skip to main content
Objects and Methods
The following changes were made to objects and methods.
Power Reservoir
The following changes were made to Power Reservoir methods.
Frequency Regulation Category
See the special attention note about Frequency Regulation Category
Unit Generator Power Method
See the special attention note about Unit Generator Power Unit-level Outputs.
Reservoir CRSS Bank Storage Method
The CRSS Bank Storage method was modified to use the lower bound on the Bank Storage slot. Now, the Bank Storage cannot go below that lower bound, if specified. No numerical differences are expected unless you specify a the lower bound in the slot configuration window. This change was added to address bank storage salinity calculations that became unstable if bank storage became negative.